Commit 0655b262 authored by Tom Lane's avatar Tom Lane

log_destination should only be PGC_SIGHUP, not PGC_POSTMASTER, as per

discussion yesterday.  Also a few improvements in the associated
documentation.
parent cbcd8b5b
<!-- <!--
$PostgreSQL: pgsql/doc/src/sgml/maintenance.sgml,v 1.35 2004/05/16 19:34:46 momjian Exp $ $PostgreSQL: pgsql/doc/src/sgml/maintenance.sgml,v 1.36 2004/07/24 19:51:22 tgl Exp $
--> -->
<chapter id="maintenance"> <chapter id="maintenance">
...@@ -456,7 +456,7 @@ VACUUM ...@@ -456,7 +456,7 @@ VACUUM
The simplest production-grade approach to managing log output is to The simplest production-grade approach to managing log output is to
send it all to <application>syslog</> and let send it all to <application>syslog</> and let
<application>syslog</> deal with file rotation. To do this, set the <application>syslog</> deal with file rotation. To do this, set the
configurations parameter <literal>log_destination</> to 'syslog' (to log to configuration parameter <literal>log_destination</> to 'syslog' (to log to
<application>syslog</> only) in <filename>postgresql.conf</>. Then <application>syslog</> only) in <filename>postgresql.conf</>. Then
you can send a <literal>SIGHUP</literal> signal to the you can send a <literal>SIGHUP</literal> signal to the
<application>syslog</> daemon whenever you want to force it to <application>syslog</> daemon whenever you want to force it to
......
<!-- <!--
$PostgreSQL: pgsql/doc/src/sgml/runtime.sgml,v 1.269 2004/07/11 00:18:40 momjian Exp $ $PostgreSQL: pgsql/doc/src/sgml/runtime.sgml,v 1.270 2004/07/24 19:51:22 tgl Exp $
--> -->
<Chapter Id="runtime"> <Chapter Id="runtime">
...@@ -1769,12 +1769,13 @@ SET ENABLE_SEQSCAN TO OFF; ...@@ -1769,12 +1769,13 @@ SET ENABLE_SEQSCAN TO OFF;
<listitem> <listitem>
<para> <para>
<productname>PostgreSQL</productname> supports several methods <productname>PostgreSQL</productname> supports several methods
for loggning, including <systemitem>stderr</systemitem> and for logging server messages, including
<systemitem>stderr</systemitem> and
<systemitem>syslog</systemitem>. On Windows, <systemitem>syslog</systemitem>. On Windows,
<systemitem>eventlog</systemitem> is also supported. Set this <systemitem>eventlog</systemitem> is also supported. Set this
option to a list of desired log destinations separated by a option to a list of desired log destinations separated by
comma. The default is to log to <systemitem>stderr</systemitem> commas. The default is to log to <systemitem>stderr</systemitem>
only. This option must be set at server start. only.
</para> </para>
</listitem> </listitem>
</varlistentry> </varlistentry>
...@@ -1783,15 +1784,16 @@ SET ENABLE_SEQSCAN TO OFF; ...@@ -1783,15 +1784,16 @@ SET ENABLE_SEQSCAN TO OFF;
<term><varname>syslog_facility</varname> (<type>string</type>)</term> <term><varname>syslog_facility</varname> (<type>string</type>)</term>
<listitem> <listitem>
<para> <para>
This option determines the <application>syslog</application> If logging to <application>syslog</> is enabled, this option
<quote>facility</quote> to be used when logging via determines the <application>syslog</application>
<application>syslog</application> is enabled. You may choose <quote>facility</quote> to be used. You may choose
from <literal>LOCAL0</>, <literal>LOCAL1</>, from <literal>LOCAL0</>, <literal>LOCAL1</>,
<literal>LOCAL2</>, <literal>LOCAL3</>, <literal>LOCAL4</>, <literal>LOCAL2</>, <literal>LOCAL3</>, <literal>LOCAL4</>,
<literal>LOCAL5</>, <literal>LOCAL6</>, <literal>LOCAL7</>; <literal>LOCAL5</>, <literal>LOCAL6</>, <literal>LOCAL7</>;
the default is <literal>LOCAL0</>. See also the the default is <literal>LOCAL0</>. See also the
documentation of your system's documentation of your system's
<application>syslog</application>. <application>syslog</application> daemon.
This option can only be set at server start.
</para> </para>
</listitem> </listitem>
</varlistentry> </varlistentry>
...@@ -1803,8 +1805,9 @@ SET ENABLE_SEQSCAN TO OFF; ...@@ -1803,8 +1805,9 @@ SET ENABLE_SEQSCAN TO OFF;
If logging to <application>syslog</> is enabled, this option If logging to <application>syslog</> is enabled, this option
determines the program name used to identify determines the program name used to identify
<productname>PostgreSQL</productname> messages in <productname>PostgreSQL</productname> messages in
<application>syslog</application> log messages. The default is <application>syslog</application> logs. The default is
<literal>postgres</literal>. <literal>postgres</literal>.
This option can only be set at server start.
</para> </para>
</listitem> </listitem>
</varlistentry> </varlistentry>
......
...@@ -10,7 +10,7 @@ ...@@ -10,7 +10,7 @@
* Written by Peter Eisentraut <peter_e@gmx.net>. * Written by Peter Eisentraut <peter_e@gmx.net>.
* *
* IDENTIFICATION * IDENTIFICATION
* $PostgreSQL: pgsql/src/backend/utils/misc/guc.c,v 1.223 2004/07/21 20:34:46 momjian Exp $ * $PostgreSQL: pgsql/src/backend/utils/misc/guc.c,v 1.224 2004/07/24 19:51:23 tgl Exp $
* *
*-------------------------------------------------------------------- *--------------------------------------------------------------------
*/ */
...@@ -1625,8 +1625,8 @@ static struct config_string ConfigureNamesString[] = ...@@ -1625,8 +1625,8 @@ static struct config_string ConfigureNamesString[] =
}, },
{ {
{"log_destination", PGC_POSTMASTER, LOGGING_WHERE, {"log_destination", PGC_SIGHUP, LOGGING_WHERE,
gettext_noop("Sets the target for log output."), gettext_noop("Sets the destination for server log output."),
gettext_noop("Valid values are combinations of stderr, syslog " gettext_noop("Valid values are combinations of stderr, syslog "
"and eventlog, depending on platform."), "and eventlog, depending on platform."),
GUC_LIST_INPUT GUC_LIST_INPUT
...@@ -5099,15 +5099,12 @@ assign_log_destination(const char *value, bool doit, GucSource source) ...@@ -5099,15 +5099,12 @@ assign_log_destination(const char *value, bool doit, GucSource source)
} }
} }
if (doit)
Log_destination = newlogdest;
pfree(rawstring); pfree(rawstring);
list_free(elemlist); list_free(elemlist);
/* If we aren't going to do the assignment, just return OK indicator. */
if (!doit)
return value;
Log_destination = newlogdest;
return value; return value;
} }
......