Avoid possible hang during smart shutdown.
If a smart shutdown occurs just as a child is starting up, and the child subsequently becomes a walsender, there is a race condition: the postmaster might count the exstant backends, determine that there is one normal backend, and wait for it to die off. Had the walsender transition already occurred before the postmaster counted, it would have proceeded with the shutdown. To fix this, have each child that transforms into a walsender kick the postmaster just after doing so, so that the state machine is certain to advance. Fujii Masao